Trailing-Edge
-
PDP-10 Archives
-
tops20-v7-ft-dist2-clock
-
7-documentation/utility.tco
There are 7 other files named utility.tco in the archive. Click here to see a list.
TCO-number: 7.1256
Written-by: WONG Creation-date: 8-Mar-88 11:36:26
Edit-checked: No Document: No TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: actsym
Problem: ACTSYM.MAC on TOPS-20 is different then on TOPS-10.
Diagnosis: Edits were made on the 10 and never got updated on the 20 and
vic verser.
Solution: Merge both ACTSYM.MAC into one.
[End of TCO 7.1256]
TCO-number: 7.1146
Written-by: MCCOLLUM Creation-date: 24-Nov-87 15:26:31
Edit-checked: No Document: Yes TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: CHKPNT
Problem:
CHKPNT can't find SYSTEM-DATA.BIN.
Diagnosis:
CHKPNT looks for this file on PS:<SYSTEM>. If a Login Structure is in use,
the file is not on PS:.
Solution:
Change CHKPNT to look for the file on ACCOUNT:, which is defined by the
monitor at startup as BS:<SYSTEM>. Note that the monitor uses this logical
name when writing to the file.
[End of TCO 7.1146]
TCO-number: 7.1171
Written-by: GSCOTT Creation-date: 5-Jan-88 14:52:30
Edit-checked: No Document: No TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: CHKPNT
Problem:
CHKPNT column overflows after edit 131.
Diagnosis:
Edit 131 had a problem in the offsets used in the usage data templates.
Solution:
Use the correct offsets.
[End of TCO 7.1171]
TCO-number: 7.1154
Written-by: MCCOLLUM Creation-date: 1-Dec-87 17:43:12
Edit-checked: No Document: Yes TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: DLUSER
Problem:
When loading directories onto a structure, DLUSER will never change
the parameters for a directory that already exists unless it is a
system directory.
Diagnosis:
That is the way DLUSER is coded.
Solution:
Implement a /FORCE switch for the load command. When this switch is typed,
DLUSER will always change the parameters for any directory found in the
input file, regardless of its directory number.
[End of TCO 7.1154]
TCO-number: 7.1028
Written-by: RASPUZZI Creation-date: 28-Jul-87 14:35:06
Edit-checked: No Document: No TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: MONSYM
Problem:
Silly error coming out of TCP code.
Diagnosis:
Misspelling of "retansmission".
Solution:
Fix spelling error.
[End of TCO 7.1028]
TCO-number: 7.1123
Written-by: GSCOTT Creation-date: 10-Nov-87 16:49:58
Edit-checked: No Document: Yes TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: MONSYM
Problem:
Brain damage evident in MONSYM.
Diagnosis:
The .DBTIM symbol is defined twice with different values.
The .DBTVS symbol is not defined.
Solution:
Define .DBTVS properly.
[End of TCO 7.1123]
TCO-number: 7.1234
Written-by: RASPUZZI Creation-date: 19-Feb-88 08:47:20
Edit-checked: No Document: No TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: MONSYM
Related-QAR: 100
Problem:
ARGX27 misspelled in MONSYM.
Diagnosis:
Extra non-functional "b".
Solution:
Remove said "b"
[End of TCO 7.1234]
TCO-number: 7.1248
Written-by: GSCOTT Creation-date: 1-Mar-88 15:26:12
Edit-checked: No Document: No TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: MONSYM
Problem:
Wrong value of .QBDMX.
Diagnosis:
Somehow there a a .QBDMX==4 after .QBDMX==5.
Solution:
Remove extra bad definition of .QBDMX.
[End of TCO 7.1248]
TCO-number: 7.1263
Written-by: RASPUZZI Creation-date: 24-Mar-88 14:21:29
Edited-by: RASPUZZI Edit-date: 25-Mar-88 08:31:09
Edit-checked: No Document: Yes TCO-tested: No
Maintenance-release: No Hardware-related: No
Program: MONSYM
Routines-affected: MONSYM
Problem:
JSYS manual talks about a TCP JFN function number 0. That's
nice but there is no indication of any such beast.
Diagnosis:
Forgetfulness.
Solution:
Add .TCMWD (default mode) to MONSYM as function 0. Also
change the documentation to reflect the correct actions
for TCP JFN modes.
[End of TCO 7.1263]