;DSKCG
IDENTIFICATION
--------------
PRODUCT CODE: AH-F466B-DD
DIAGNOSTIC CODE: DSKCG
PRODUCT NAME: DSKCGB0 DECSYSTEM 2020 ADVANCED INSTRUCTION
DIAGNOSTIC #7
VERSION: 0.2
DATE RELEASED: SEPTEMBER 1979
MAINTAINED BY: DIAGNOSTIC ENGINEERING
AUTHOR: JOHN R. KIRCHOFF
KATHY J. ATKINS
COPYRIGHT (C) 1979
DIGITAL EQUIPMENT CORPORATION, MAYNARD, MASS.
THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY ON A
SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH THE INCLUSION
OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE, OR ANY OTHER
COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE
TO ANY OTHER PERSON EXCEPT FOR USE ON SUCH SYSTEM AND TO ONE WHO
AGREES TO THESE LICENSE TERMS. TITLE TO AND OWNERSHIP OF THE
SOFTWARE SHALL AT ALL TIMES REMAIN IN DIGITAL EQUIPMENT
CORPORATION.
THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
EQUIPMENT CORPORATION.
DIGITAL EQUIPMENT CORPORATION ASSUMES NO RESPONSIBILITY FOR THE
USE OR RELIABILITY OF ITS SOFTWARE IN EQUIPMENT WHICH IS NOT
SUPPLIED BY DIGITAL EQUIPMENT CORPORATION.
TABLE OF CONTENTS
-----------------
1.0 ABSTRACT
2.0 REQUIREMENTS
2.1 EQUIPMENT
2.2 STORAGE
2.3 PRELIMINARY PROGRAMS
3.0 PROGRAM PROCEDURES
3.1 LOADING PROCEDURE
3.2 STARTING PROCEDURE
3.3 OPERATING PROCEDURE
4.0 DATA SWITCH FUNCTIONS
5.0 ERRORS
6.0 ITERATION COUNTER
7.0 OPERATIONAL VARIATIONS
8.0 LISTING
1.0 ABSTRACT
THIS DECSYSTEM 2020 ADVANCED INSTRUCTION DIAGNOSTIC IS THE
SEVENTH IN A SERIES OF DECSYSTEM 2020 ADVANCED PROCESSOR
DIAGNOSTICS.
THE DIAGNOSTIC PERFORMS TESTING OF THE KS10 MICRO-CODE
FOR THE EXTENDED INSTRUCTION SET.
THIS INSTRUCTION SET IS FOR HANDLING STRINGS. ALL STRING
INSTRUCTIONS ARE IN THE EXTENDED INSTRUCTION SET, AND ALL
THEREFORE HAVE A TWO WORD FORMAT, THE FIRST WORD BEING
EXTEND. THE SECOND INSTRUCTION WORD, WHOSE OWN EFFECTIVE
ADDRESS IS E1, IS AT LOCATION E0, WHICH IS THE EFFECTIVE ADDRESS
OF THE EXTEND. AN INSTRUCTION THAT "OFFSETS" USES E1 AS A
SIGNED OFFSET, IN WHICH BIT 18 IS THE SIGN. AN INSTRUCTION THAT
"TRANSLATES" OR "EDITS" MAKES USE OF A TRANSLATION TABLE THAT
BEGINS AT E1.
THE INSTRUCTIONS TESTED ARE:
MOVES:
MOVSLJ - MOVE STRING LEFT JUSTIFIED
MOVSO - MOVE STING OFFSET
MOVST - MOVE STRING TRANSLATED
MOVSRJ - MOVE STRING RIGHT JUSTIFIED
COMPARE STRINGS:
CMPSL - SKIP IF STRING 1 LESS THAN STRING 2
CMPSE - SKIP IF STRING 1 EQUAL TO STRING 2
CMPSLE - SKIP IF STRING 1 LESS THAN OR EQUAL TO STING 2
CMPSGE - SKIP IF STRING 1 GREATER THAN OR EQUAL TO STING 2
CMPSN - SKIP IF STRING 1 NOT EQUAL TO STING 2
CMPSG - SKIP IF STRING 1 GREATER THAN STRING 2
DECIMAL CONVERSIONS:
CVTBDO - CONVERT BINARY TO DECIMAL OFFSET
CVTBDT - CONVERT BINARY TO DECIMAL TRANSLATED
CVTDBO - CONVERT DECIMAL TO BINARY OFFSET
CVTDBT - CONVERT DECIMAL TO BINARY TRANSLATED
STRING EDITING:
EDIT - EDIT STRING
2.0 REQUIREMENTS
2.1 EQUIPMENT
A DECSYSTEM 2020 EQUIPPED WITH A MINIMUM OF 32K OF MEMORY
CONSOLE PROCESSOR
CONSOLE TELETYPE
LOAD DEVICE
2.2 STORAGE
THE PROGRAM RUNS WITHIN 32K OF MEMORY.
2.3 PRELIMINARY PROGRAMS
PREVIOUS PROCESSOR DIAGNOSTICS
3.0 PROGRAM PROCEDURES
3.1 LOADING PROCEDURE
THIS DIAGNOSTIC REQUIRES THAT THE DECSYSTEM 2020 SUBROUTINE
PROGRAM BE RESIDENT IN THE DECSYSTEM 2020.
FOLLOW THE APPROPRIATE DIAGNOSTIC LOADING PROCEDURES.
3.2 STARTING PROCEDURE
A. SELECT OPERATIONAL CONSOLE DATA SWITCH SETTINGS (REFER TO
4.0 DATA SWITCH FUNCTIONS).
RUN UNDER "SMMON".
THE FOLLOWING QUESTIONS WILL BE ASKED TO
SELECT THE OPERATIONAL SWITCHES:
TELETYPE SWITCH CONTROL ? 0,S OR Y (CR) -
IF THE OPERATOR TYPES "Y", THE FOLLOWING QUESTIONS
ARE ASKED AND THE OPERATOR RESPONDS BY TYPING
THE ANSWER AS SIX OCTAL DIGITS REPRESENTING
THE DESIRED SWITCH SETTINGS.
SPECIFY LH SWITCHES IN OCTAL-
SPECIFY RH SWITCHES IN OCTAL- TYPE 0
****** (THERE ARE NO RH SWITCHES)
IF THE OPERATOR TYPES "0", ZERO'S ARE USED FOR
THE SWITCH SETTINGS.
IF THE OPERATOR TYPES "S", PREVIOUSLY SET SWITCHES
ARE USED. THIS IS ONLY VALID UPON RESTARTING
OF AN INTERRUPTED PROGRAM.
3.3 OPERATING PROCEDURE
A. ERROR INFORMATION MAY BE OBTAINED QUICKLY BY PRINTING
ERRORS ON THE LINE PRINTER.
B. IN THE EVENT OF A PRINT ROUTINE FAILURE THE 'NOPNT' SWITCH
AND THE 'ERSTOP' SWITCH MAY BE SET TO INHIBIT PRINTOUT
BUT HALT THE PROGRAM POINTING TO THE ERROR.
4.0 DATA SWITCH FUNCTIONS
SWITCH STATE FUNCTION
------ ----- --------
0 ABORT 0 NORMAL OPERATION
1 ABORT AT END OF PASS
1 RSTART NOT USED
2 TOTALS NOT USED
3 NOPNT 0 NORMAL TYPEOUT
1 INHIBIT ALL PRINT/TYPEOUT
(EXCEPT FORCED)
4 PNTLPT 0 NORMAL OUTPUT TO TTY
1 PRINT ALL DATA ON LPT
(LOGICAL DEVICE, USER MODE)
5 DING 0 NO FUNCTION
1 RING TTY BELL ON ERROR
6 LOOPER 0 PROCEED TO NEXT TEST
1 ENTER LOOP ON TEST ERROR
7 ERSTOP 0 NO FUNCTION
1 HALT ON TEST ERROR
8 PALERS 0 PRINT ONLY FIRST ERROR WHEN LOOPING
1 PRINT ALL ERRORS, EVEN IF SAME ERROR
9 RELIAB 0 FAST CYCLE (1 PASS)
1 REPETITION COUNT OF 10
10 TXTINH 0 PRINT FULL ERROR MESSAGES.
1 INHIBIT COMMENT PORTION OF
ERROR MESSAGES.
11 INHPAG 0 ALLOW PAGING AND TRAP ENABLE
1 INHIBIT PAGING AND TRAPPING
12 MODDVC NOT USED
13 INHCSH 0 ALLOW CACHE USE
1 INHIBIT CACHE
5.0 ERRORS
ERRORS ARE PRINTED ON THE TTY OR LINE PRINTER. THERE ARE
TWO TYPES OF PROGRAM ERROR PRINTOUT.
THE FIRST TYPE IS THE STANDARD SUBROUTINE PACKAGE ERROR MACRO
PRINTOUT. IT IS USED FOR REPORTING ERRORS IN THE MUUO TRAP TESTING
AND THE PAGE FAIL TEST.
PRINTOUT CONTAINS THE TEST TITLE, THE PC OF THE FAILURE, ERROR
NUMBER AND THE CONTENTS OF AN APPLICABLE AC (CORRECT DATA,
ACTUAL DATA, AND THE DISCREPANCY BETWEEN THE TWO.)
THE PC VALUE IS USEFUL IN RELATING THE FAILURE TO THE LISTING.
THE ERROR NUMBER IS PROVIDED SUCH THAT AN ERROR DICTIONARY MAY
BE MADE AT SOME FUTURE DATE.
THE SECOND TYPE IS IMPLEMENTED COMPLETELY IN THE PROGRAM.
THIS TYPE OF ERROR REPORT IS USED IN ALL INSTRUCTION CASE
TESTING, AND THE INTERRUPTABILITY TEST.
PRINTOUT FOR CASE TESTING ERROR CONTAINS THE INITIAL AC BLOCK
DATA, ACTUAL AC BLOCK RESULT, AND CORRECT AC BLOCK RESULT.
DEPENDING ON THE INSTRUCTION THE SOURCE,DESTINATION AND SIMULATED
DESTINATION STRINGS ARE PRINTED. E0+1 AND E0+2 WORDS ARE PRINTED
IF APPLICABLE. IF THE INSTRUCTION TOOK AN INCORRECT SKIP OR NON-
SKIP RETURN THIS IS ALSO PRINTED.
6.0 ITERATION COUNTER
THE ITERATION COUNT OF THE PROGRAM IS PRINTED BY THE
CONSOLE PROCESSOR.
7.0 OPERATIONAL VARIATIONS
A. DIAGNOSTIC MONITOR
THE PROGRAM IS USABLE WITH THE DIAGNOSTIC MONITOR TO PROVIDE
RELIABILITY AND ACCEPTANCE TESTS FOR THE EXTENDED
INSTRUCTION SET MICRO-CODE. THE FOLLOWING INFORMATION MAY
BE USEFUL:
1. THE DIAGNOSTIC MONITOR TRANSFERS CONTROL TO THE PROGRAM
AND STARTS IT AT LOCATION 30002.
2. MONCTL - LOCATION 30043 IS USED AS THE DIAGNOSTIC MONITOR
CONTROL WORD.
LH = 0, STAND-ALONE OPERATION
-1, RUNNING UNDER DIAGNOSTIC MONITOR
RH = RIGHT HALF OF CONSOLE SWITCHES IF UNDER
DIAGNOSTIC MONITOR CONTROL.
B. USER MODE
TO OUTPUT THE PRINTED ERROR MESSAGES TO A USER SPECIFIED
DEVICE IN USER MODE, ASSIGN THE DESIRED OUTPUT DEVICE TO
DEVICE NAME 'DEV' AND SET SWITCH 'PNTLPT'. THE PHYSICAL
DEVICE USED CAN BE ANY DEVICE THAT CAN ACCEPT ASCII OUTPUT
FORMAT SUCH AS LPT, DSK, DTA, ETC. THE CORRESPONDING
OUTPUT FILE IS 'DSKCB.LPT'
EXAMPLE DEVICE ASSIGNMENT:
.ASSIGN DSK DEV
IN USER MODE THE PROGRAM WILL MAKE 1000(8) PASSES AND THEN
RETURN TO SMMON COMMAND MODE.
7.0 OPERATIONAL VARIATIONS (CON'T)
THE OUTPUT FILE (IF USED) MAY THEN BE LISTED BY USING THE
NORMAL MONITOR COMMANDS (PRINT, LIST, TYPE, PIP, ETC.).
IF THE PROGRAM IS ABORTED BEFORE COMPLETION (BY ^C, ETC.) THE
OUTPUT FILE MAY BE CLOSED BY USING THE MONITOR 'REENTER'
COMMAND.
C. SYSTEM EXERCISER
START ADDRESS IS 30003. DATA SWITCHES ARE PRESTORED IN
'SWTEXR' LOC 30023.
8.0 LISTING