MAINDEC-10-DBKAF.TXT
IDENTIFICATION
--------------
PRODUCT CODE: MAINDEC-10-DBKAF
PRODUCT NAME: DECSYSTEM10 PDP-10 KI10 BASIC
INSTRUCTION DIAGNOSTIC (6)
FUNCTION: BOOLE, HWT, TEST
VERSION: 0.2
DATE RELEASED: AUGUST,1976
MAINTAINED BY: DIAGNOSTIC ENGINEERING GROUP
AUTHOR: JOHN R. KIRCHOFF
COPYRIGHT(C) 1976
DIGITAL EQUIPMENT CORPORATION
MARLBORO, MASS. 01752
THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY
ON A SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH
THE INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE,
OR ANY OTHER COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE
MADE AVAILABLE TO ANY OTHER PERSON EXECPT FOR USE ON SUCH SYSTEM
AND TO ONE WHO AGREES TO THESE LICENSE TERMS. TITLE TO AND
OWNERSHIP OF THE SOFTWARE SHALL AT ALL TIMES REMAIN IN DEC.
THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
EQUIPMENT CORPORATION.
DEC ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DEC.
MAINDEC-10-DBKAF.TXT
PAGE 2
TABLE OF CONTENTS
-----------------
1.0 ABSTRACT
2.0 REQUIREMENTS
2.1 EQUIPMENT
2.2 STORAGE
2.3 PRELIMINARY PROGRAMS
3.0 PROGRAM PROCEDURES
3.1 LOADING PROCEDURE
3.2 STARTING PROCEDURE
3.3 OPERATING PROCEDURE
4.0 ERRORS
5.0 ITERATION COUNTER
6.0 CYCLE TIME
7.0 OPERATIONAL VARIATIONS
8.0 MISCELLANEOUS
9.0 LISTING
MAINDEC-10-DBKAF.TXT
PAGE 3
1.0 ABSTRACT
THIS PDP-10 KI10 BASIC INSTRUCTION DIAGNOSTIC IS THE
SIXTH IN A SERIES OF PDP-10 KI10 PROCESSOR DIAGNOSTICS.
THE DIAGNOSTIC TESTS THE BOOLE, HWT AND TEST INSTRUCTIONS.
2.0 REQUIREMENTS
2.1 EQUIPMENT
A PDP-10 KI10 WITH A MINIMUM OF 32K OF MEMORY
PAPER TAPE READER (KI10)
DECTAPE (OPTIONAL)
CONSOLE TELETYPE
2.2 STORAGE
THE PROGRAM RUNS WITHIN 32K OF MEMORY.
2.3 PRELIMINARY PROGRAMS
CONSOLE FUNCTIONS WORKING PROPERLY
PAPER TAPE READ-IN WORKING PROPERLY (KI10)
PREVIOUS PROCESSOR DIAGNOSTICS
MAINDEC-10-DBKAF.TXT
PAGE 4
3.0 PROGRAM PROCEDURES
3.1 LOADING PROCEDURE
PAPER TAPE - HARDWARE READ-IN (READER DEVICE CODE 104)
DECTAPE - LOAD WITH DIAMON (DECTAPE DEVICE CODE 320)
3.2 STARTING PROCEDURE
STAND-ALONE STARTING ADDRESS IS 30000.
IF THE DIAGNOSTIC FAILS TO START CORRECTLY TRY STARTING AT THE
FIRST TEST INSTEAD OF AT THE BEGINNING OF THE CONTROL SEQUENCE.
(SEE LISTING).
3.3 OPERATING PROCEDURE
ONCE STARTED THE PROGRAM WILL CYCLE CONTINUALLY UNTIL STOPPED
OR AN ERROR OCCURS.
4.0 ERRORS
ERRORS ARE IN THE FORM OF HALT INSTRUCTIONS. THE LISTING
SHOULD BE CONSULTED TO DETERMINE THE CAUSE OF THE ERROR. A
NO OPERATION (JUMP) INSTRUCTION FOLLOWS EACH HALT. THIS
MAY BE USEFUL IN CONSTRUCTING A SCOPE LOOP TO CYCLE ON THE
FAILING INSTRUCTION.
5.0 ITERATION COUNTER
THE ITERATION COUNT OF THE PROGRAM IS DISPLAYED IN THE MEM-
ORY INDICATORS (MI). THIS COUNT IS A DECREMENTING COUNT AND
INITIALLY STARTS AT -1 IN STAND-ALONE OPERATION.
6.0 CYCLE TIME
THE CYCLE TIME OF THE PROGRAM IS IN THE MILLISECOND RANGE AND
IS THEREFORE SUITABLE FOR TAKING MARGINS, VIBRATION TESTS, ETC.
MAINDEC-10-DBKAF.TXT
PAGE 5
7.0 OPERATIONAL VARIATIONS
A. DIAGNOSTIC MONITOR
THE PROGRAM IS USABLE WITH THE DIAGNOSTIC MONITOR TO PRO-
VIDE RELIABILITY TESTS, ACCEPTANCE TESTS, AND/OR TO PRO-
VIDE A QUICK METHOD OF ISOLATION OF A FAULT TO A PARTICULAR
AREA OF THE PROCESSOR. CERTAIN PROCEDURES ARE USED WHEN
THE PROGRAM IS USED IN THIS MANNER. THEY ARE:
1. THE DIAGNOSTIC MONITOR TRANSFERS CONTROL TO THE PRO-
GRAM AND STARTS IT AT LOCATION 30002.
2. MONCTL - LOCATION 30043 IS USED AS THE DIAGNOSTIC MON-
ITOR CONTROL FLAG WORD.
B. USER MODE
THE PROGRAM WILL OPERATE IN USER MODE AND AS SUCH PROVIDES
ASSURANCE THAT THE PROCESSOR IS PERFORMING ALL FUNCTIONS
CORRECTLY. USER MODE STARTING ADDRESS IS 30000.
C. SYSTEM EXERCISER
STARTING ADDRESS IS 30003. NO DATA SWITCHES ARE USED BY
THIS PROGRAM.
8.0 MISCELLANEOUS
NONE
9.0 LISTING