MAINDEC-10-DBKAD.TXT






 
				IDENTIFICATION
				--------------


	PRODUCT CODE:	MAINDEC-10-DBKAD

	PRODUCT NAME:	DECSYSTEM10 PDP-10 KI10 BASIC
			INSTRUCTION DIAGNOSTIC (4)

	FUNCTION:	REGISTER ADDRESSING, PC CHANGE, XCT

	VERSION:	0.2

	DATE RELEASED:	AUGUST,1976

	MAINTAINED BY:	DIAGNOSTIC ENGINEERING GROUP

	AUTHOR:		JOHN R. KIRCHOFF

COPYRIGHT(C) 1976
DIGITAL EQUIPMENT CORPORATION
MARLBORO, MASS. 01752

THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY
ON A SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH
THE INCLUSION OF THE ABOVE COPYRIGHT NOTICE.  THIS SOFTWARE,
OR ANY OTHER COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE
MADE AVAILABLE TO ANY OTHER PERSON EXECPT FOR USE ON SUCH SYSTEM
AND TO ONE WHO AGREES TO THESE LICENSE TERMS.  TITLE TO AND
OWNERSHIP OF THE SOFTWARE SHALL AT ALL TIMES REMAIN IN DEC.

THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
EQUIPMENT CORPORATION.

DEC ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DEC.
							MAINDEC-10-DBKAD.TXT
							PAGE 2


			TABLE OF CONTENTS
			-----------------

1.0	ABSTRACT

2.0	REQUIREMENTS

2.1	EQUIPMENT

2.2	STORAGE

2.3	PRELIMINARY PROGRAMS

3.0	PROGRAM PROCEDURES

3.1	LOADING PROCEDURE

3.2	STARTING PROCEDURE

3.3	OPERATING PROCEDURE

4.0	ERRORS

5.0	ITERATION COUNTER

6.0	CYCLE TIME

7.0	OPERATIONAL VARIATIONS

8.0	MISCELLANEOUS

9.0	LISTING
							MAINDEC-10-DBKAD.TXT
							PAGE 3


1.0	ABSTRACT

	THIS PDP-10 KI10 BASIC INSTRUCTION DIAGNOSTIC IS THE
	FOURTH IN A SERIES OF PDP-10 KI10 PROCESSOR DIAGNOSTICS.
	THE DIAGNOSTIC TESTS REGISTER ADDRESSING, JFCL, AR FLAGS,
	AOS, SOS, JRST, AOBJX, JSP, XCT, INDIRECT AND
	INDEXED ADDRESSING.

2.0	REQUIREMENTS

2.1	EQUIPMENT

	A PDP-10 KI10 WITH A MINIMUM OF 32K OF MEMORY

	PAPER TAPE READER (KI10)
	DECTAPE (OPTIONAL)
	CONSOLE TELETYPE

2.2	STORAGE

	THE PROGRAM RUNS WITHIN 32K OF MEMORY.

2.3	PRELIMINARY PROGRAMS

	CONSOLE FUNCTIONS WORKING PROPERLY
	PAPER TAPE READ-IN WORKING PROPERLY (KI10)
	PREVIOUS PROCESSOR DIAGNOSTICS
							MAINDEC-10-DBKAD.TXT
							PAGE 4


3.0	PROGRAM PROCEDURES

3.1	LOADING PROCEDURE

	PAPER TAPE - HARDWARE READ-IN (READER DEVICE CODE 104)
	DECTAPE - LOAD WITH DIAMON (DECTAPE DEVICE CODE 320)

3.2	STARTING PROCEDURE

	STAND-ALONE STARTING ADDRESS IS 30000.

	IF THE DIAGNOSTIC FAILS TO START CORRECTLY TRY STARTING AT THE
	FIRST TEST INSTEAD OF AT THE BEGINNING OF THE CONTROL SEQUENCE.
	(SEE LISTING).

3.3	OPERATING PROCEDURE

	ONCE STARTED THE PROGRAM WILL CYCLE CONTINUALLY UNTIL STOPPED
	OR AN ERROR OCCURS.

4.0	ERRORS

	ERRORS ARE IN THE FORM OF HALT INSTRUCTIONS.  THE LISTING
	SHOULD BE CONSULTED TO DETERMINE THE CAUSE OF THE ERROR.  A
	NO OPERATION (JUMP) INSTRUCTION FOLLOWS EACH HALT.  THIS
	MAY BE USEFUL IN CONSTRUCTING A SCOPE LOOP TO CYCLE ON THE
	FAILING INSTRUCTION.

5.0	ITERATION COUNTER

	THE ITERATION COUNT OF THE PROGRAM IS DISPLAYED IN THE MEM-
	ORY INDICATORS (MI).  THIS COUNT IS A DECREMENTING COUNT AND
	INITIALLY STARTS AT -1 IN STAND-ALONE OPERATION.

6.0	CYCLE TIME

	THE CYCLE TIME OF THE PROGRAM IS IN THE MILLISECOND RANGE AND
	IS THEREFORE SUITABLE FOR TAKING MARGINS, VIBRATION TESTS, ETC.

							MAINDEC-10-DBKAD.TXT
							PAGE 5


7.0	OPERATIONAL VARIATIONS

	A.  DIAGNOSTIC MONITOR

	    THE PROGRAM IS USABLE WITH THE DIAGNOSTIC MONITOR TO PRO-
	    VIDE RELIABILITY TESTS, ACCEPTANCE TESTS, AND/OR TO PRO-
	    VIDE A QUICK METHOD OF ISOLATION OF A FAULT TO A PARTICULAR
	    AREA OF THE PROCESSOR.  CERTAIN PROCEDURES ARE USED WHEN
	    THE PROGRAM IS USED IN THIS MANNER.  THEY ARE:

	    1.  THE DIAGNOSTIC MONITOR TRANSFERS CONTROL TO THE PRO-
		GRAM AND STARTS IT AT LOCATION 30002.

	    2.  MONCTL - LOCATION 30043 IS USED AS THE DIAGNOSTIC MON-
		ITOR CONTROL FLAG WORD.

	B.  USER MODE

	    THE PROGRAM WILL OPERATE IN USER MODE AND AS SUCH PROVIDES
	    ASSURANCE THAT THE PROCESSOR IS PERFORMING ALL FUNCTIONS
	    CORRECTLY.  USER MODE STARTING ADDRESS IS 30000.

	C.  SYSTEM EXERCISER

	    STARTING ADDRESS IS 30003.  NO DATA SWITCHES ARE USED BY
	    THIS PROGRAM.

8.0	MISCELLANEOUS

	NONE

9.0	LISTING