Trailing-Edge
-
PDP-10 Archives
-
k20v7b
-
help/readme.hlp
There is 1 other file named readme.hlp in the archive. Click here to see a list.
README HELP
GENERAL INSTRUCTIONS FOR THE PM PACKAGE
THIS PM PACKAGE IS DESIGNED TO HELP FIELD SERVICE PEOPLE
MAINTAIN A DECSYSTEM-10/20 TO A HIGH DEGREE OF RELIABILITY. IT
INCLUDES PROCEDURES AND SPECIFICATIONS FOR MOST EQUIPMENT AND WILL
BE UPDATED PERIODICALLY TO INCLUDE NEW EQUIPMENT AND REVISED
PROCEDURES.
IN THE PACKAGE IS A SCHEDULING PROGRAM WHICH WILL SCHEDULE
WHAT TASKS TO DO FOR EACH OF 26 WEEKS. FOR A DESCRIPTION OF THIS
PROGRAM, INCLUDING INSTRUCTIONS FOR ITS USE, SEE SCHED.HLP. THE
TIMES GENERATED BY THIS PROGRAM REFLECT THE AVERAGE AMOUNT OF TIME
NEEDED TO PERFORM THE PM AND MAKE MINOR ADJUSTMENTS. IF A FAULT
REQUIRING EXTENDED REPAIR TIME IS FOUND DURING THE PM, THE ENGINEER
SHOULD SCHEDULE ADDITIONAL TIME OUTSIDE OF PM TO MAKE THE REPAIR.
ONLY PM'S SHOULD BE DONE DURING PM TIME.
THIS CONCEPT PRESENTS THREE TYPES OF MAINTENANCE, NAMELY
UNSCHEDULED CORRECTIVE MAINTENANCE, PREVENTATIVE MAINTENANCE AND
SCHEDULED MAINTENANCE.
UNSCHEDULED CORRECTIVE MAINTENANCE IS PERFORMED WHENEVER THE
SYSTEM IS NOT WORKING AS INTENDED AND THEREFORE THE WHOLE SYSTEM IS
GIVEN TO FIELD SERVICE. AN EXAMPLE MIGHT BE A SOLID FAULT IN THE
KA10 OR RP10. THIS TIME IS ALSO CALLED "DOWNTIME" FOR PURPOSES OF
CRASH AND UPTIME REPORTING.
PREVENTATIVE MAINTENANCE IS PERIODIC CHECKS AND ADJUSTMENTS
PERFORMED TO INSURE A DEVICE IS OPERATING CORRECTLY. IT IS
INTENDED TO FIND EARLY SIGNS OF TROUBLE. IT IS NOT TIME SPENT
RUNNING DIAGNOSTICS TO TRY TO FIND WHAT IS CAUSING THAT
INTERMITTENT PARITY ERROR. FIXING THAT INTERMITTENT PARITY ERROR
SHOULD BE DONE DURING THE "SCHEDULED MAINTENANCE" PERIOD WHICH IS
SCHEDULED WITH THE CUSTOMER AS OFTEN AS REQUIRED. MAJOR OVERHAULS
SHOULD ALSO BE ACCOMPLISHED DURIND "SCHEDULED MAINTENANCE" TIME AS
WELL AS INSTALLATION OF ECO'S. REMEMBER THIS WHEN PERFORMING
PREVENTATIVE MAINTENANCE.
ALSO INCLUDED IN THIS PACKAGE IS AN ERROR REPORTING FORM WHICH
SHOULD BE USED FOR ANY COMMENTS CONCERNING MISTAKES, NEW DEVICES OR
IMPROVED PROCEDURES. THE ERROR REPORT FORM IS ON THE DISTRIBUTION
TAPE, ALONG WITH THE SCHEDULING PROGRAM, AND CAN BE PRINTED ON THE
LINE PRINTER VIA THE "PRINT" COMMAND ONCE THE FILES ARE ON THE
DISK. WE SOLICIT YOUR HELP IN MAKING THIS AN EFFECTIVE FIELD
SERVICE TOOL.