Trailing-Edge
-
PDP-10 Archives
-
dec-10-omona-u-mc9
-
x6801a.rnd
There are no other files named x6801a.rnd in the archive.
.;11-MAY-77-GR
\\
.LM0;.RM70;.F;.J;.FLAG CAP;.SP1;.TS5
<X680.DOC -- ^VERSION <1A
.BR
^APRIL 1971
.FG30
^COPYRIGHT (^C) 1971,1973,1975,1977
.BR
^DIGITAL ^EQUIPMENT ^CORPORATION, ^MAYNARD, ^MASS.
.B 2
^THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY ON A
SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH THE INCLUSION
OF THE ABOVE COPYRIGHT NOTICE. ^THIS SOFTWARE, OR ANY OTHER
COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE
TO ANY OTHER PERSON EXCEPT FOR USE ON SUCH SYSTEM AND TO ONE WHO
AGREES TO THESE LICENSE TERMS. ^TITLE TO AND OWNERSHIP OF THE
SOFTWARE SHALL AT ALL TIMES REMAIN IN ^^DEC\\.
.B 1
^THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ^DIGITAL
^EQUIPMENT ^CORPORATION.
.B 1
^^DEC\\ ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY ^^DEC\\.
.T <X6801A.DOC
.PG
<X680.DOC -- ^VERSION <1A
.BR
^APRIL 1971
.B3.LM0
1.0##<CHANGES
.B1
^VERSION-1##^UPDATE-<A
.B1
^THE RESTART PROCEDURE HAS BEEN CHANGED:
.B1
^IF FOR ANY REASON <X680 NEEDS TO BE INITIALIZED (E.G., AFTER A HALT) WITH
ACTIVE USERS CONNECTED, PERFORM THE FOLLOWING STEPS:
.B1.LM9.I-4
1.##^PRESS <STOP TO STOP THE <680I.
.B1.I-4
2.##^PUT 0001 IN THE SWITCHES AND LOAD ADDRESS
.B1.I-4
3.##^PUT 5405 IN THE SWITCHES AND DEPOSIT
.B1.I-4
4.##^RESET THE SWITCHES TO DESIRED STARTING ADDRESS AND CONTINUE
.B1.LM0
<NOTE -- ^USERS OF <P680.PAL VERSIONS BEFORE ^UPDATE-^A WILL ALSO HAVE
TO DEPOSIT 200 IN LOCATION 0005 AFTER THE DEPOSIT IN LOCATION 0001.
.B3
2.0##<DEFICIENCIES
.B1
^VERSION-1##^UPDATE-<A
.B1
^IN THE CONFIGURATION FILE (SEE <680DES.RNO), DO NOT SPECIFY ^MODEM ^CONTROL
(<MODCON=1) UNLESS YOU ACTUALLY INCLUDE SOME LINES WITH ^MODEM ^CONTROL
(^REMOTE OR ^MODEM) IN THE LINES ELEMENT.
.B3.LM0
3.0##<COMPATIBILITY <REQUIREMENTS
.B1.LM9.I-4
1.##<M680.MAC AND CONFIGURATION FILE MUST BE ASSEMBLED WITH <MACRO <V.44 AND LOADED WITH <LOADER <V.52.
.B1.I-4
2.##^ALWAYS USE ^IMAGE ^MODE (<PIP SWITCH </I) WHEN TRANSFERRING <.BIN OR <.RIM FILES (E.G., <L680.RIM).
.B1.I-4
3.##<X680 WILL RUN WITH ALL <PDP-10 MONITORS SUBJECT TO THE FOLLOWING CONSIDERATIONS:
.B1.LM9.TS15,24.NF.NJ
<X680A <L680
.B1
<4S72 (1) (2) (3)
.B2
<5S01 (1) (2) (3)
.B1
<5S02 (2) --
.B1
<5S03 -- --
.B1.LM13.F.J.I-4
A.##^THESE MONITORS DO NOT SUPPORT DATA-SET CONTROL, THEREFORE IF YOU HAVE DATA-SETS,
USE THE CONSOL <TTY TO ENABLE ALL DATA-SETS (<7777A) AND RUN WITH ^MODEM
^CONTROL DISABLED (^SWITCH-10 = 1). ^NOTE -- ^THERE WILL BE NO AUTO-DETACH
ON DATA-SET DISCONNECTS SINCE THIS IS AGAIN A FUNCTION OF THE <PDP-10 MONITOR.
.B1.I-4
B.##^RESTARTING OR RELOADING THE <PDP-10 MONITOR DOES NOT RESTART <X680 WITH THESE MONITORS.
.B1.I-4
C.##^THESE MONITORS DO NOT SUPPORT IMAGE-MODE TELETYPE OUTPUT AND THEREFORE THE
<PDP-10 TO <680I LOADER MODE WILL NOT WORK. ^THE <ASR-33 MODE WILL STILL WORK
BUT IT IS THE SAME AS THE STANDARD BINARY LOADER.
.B3.LM0
[^END OF <X6801A.DOC]