TOPS20 Change Order Number 1837
Written by: HESS 11-Jul-77 10:29:01
Edit checked: YES Document: YES
TCO Tested: YES Maintenance Release: NO
Program: CHKPNT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
NEW: UPDATE CHKPNT FOR NEW ACCOUNTING PRACTICES...
Diagnosis:
YES
Solution:
1) NO LONGER RUN CHKPNT UNDER JOB 0
2) SET COMMAND TO SET CHECKPOINT INTERVAL IN MONITOR
TOPS20 Change Order Number 1865
Written by: HESS 29-Sep-77 10:32:37
Edit checked: YES Document: YES
TCO Tested: YES Maintenance Release: NO
Program: CHKPNT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
SESSION REMARK STRINGS MAY HAVE CONTROL CHARACTERS IN THEM
Diagnosis:
YES
Solution:
REPLACE CONTROL CHARACTERS (1-37) WITH A BACK-SLASH.
TOPS20 Change Order Number 1883
Written by: HESS 4-Nov-77 13:23:03
Edit checked: YES Document: NO
TCO Tested: YES Maintenance Release: NO
Program: CHKPNT
Release: 3
Related TCO's:
Related SPR'S:
Problem:
COPY COMMAND OVERWRITING EXISTING USAGE.OUT FILES
Diagnosis:
NOT CALLING GTJFN WITH GJ%FOU BIT ON
Solution:
TURN ON GJ%FOU BIT IN GTJFN CALL IN .COPY