Trailing-Edge
-
PDP-10 Archives
-
bb-bt99g-bb
-
srtv4c.d06
There is 1 other file named srtv4c.d06 in the archive. Click here to see a list.
EDIT DESCRIPTIONS FOR SORT-10-V4C
EDIT 513 FOR SORT
[SYMPTOM]
SORT does not assemble correctly for KI-10's if built with a MACRO
that was built for KI-10's.
[DIAGNOSIS]
There is code in SORT for both KL's and KI's which is not under
conditional assembly because the check to determine which code to
execute is a runtime check. This results in the instruction EXTEND
being undefined since KI-10 MACRO does not know about it.
[CURE]
We are inserting an OPDEF to define the EXTEND instruction. The
edit defines the instruction in terms of itself. If SORT is
assembled by KI-10 MACRO, then the EXTEND is defined as zero. This
is fine since the code which contains the EXTEND instruction will
never be executed on a KI. If SORT is assembled by KL-10 MACRO,
then the EXTEND is defined as the actual instruction since this
flavour of MACRO knows about the instruction.
********************************************************************************
EDIT 514 FOR SORT
[SYMPTOM]
The code doesn't look right.
[DIAGNOSIS]
The code was actually wrong because an index AC was left off of the
SETZB instruction at USRFMT+13 in Edit 511. However, there were no
symptoms related to this because the appropriate areas were already
zero. This instruction was merely to insure that the areas were
zero.
[CURE]
Put the index AC on the instruction. The instruction should become
"SETZB T3,KY.FMT+2(T1)".
********************************************************************************
END OF SORT-10-V4C