Trailing-Edge
-
PDP-10 Archives
-
SRI_NIC_PERM_SRC_1_19910112
-
7/documentation/filcom.doc
There are 21 other files named filcom.doc in the archive. Click here to see a list.
FILCOM.DOC -- Changes from V21C(75) to V22A(117)
September 1987
COPYRIGHT (c) DIGITAL EQUIPMENT CORPORATION 1973,1978,1979,1984,1986.
ALL RIGHTS RESERVED.
THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY BE USED AND COPIED
ONLY IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE AND WITH THE
INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE OR ANY OTHER
COPIES THEREOF MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE TO ANY
OTHER PERSON. NO TITLE TO AND OWNERSHIP OF THE SOFTWARE IS HEREBY
TRANSFERRED.
THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT NOTICE
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT
CORPORATION.
DIGITAL ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DIGITAL.
FILCOM.DOC Page 2
FILCOM.DOC -- Changes from V21C(75) to V22A(117)
September 1987
1.0 SUMMARY
This is a combination of a maintenance release of FILCOM with the
added support for /Offset mode. This release will run on all
supported monitors.
2.0 EXTERNAL CHANGES
In /U mode, FILCOM will flag deleted text by a bullet (o) in the left
margin.
The /O (offset) switch has been added. If this switch is used in an
ASCII, non-/U compare, the location of differences will be reported as
closest label+offset. This assumes that the source file is a MACRO-10
or MACRO-11 file, and that labels start in the first 10 characters of
a line. PDP-11 local labels (nnn$:) are qualified by the nearest
ordinary label.
The /T switch has been added. This switch causes FILCOM to always
produce an output file, even if no differences are encountered. This
is intended for automatic procedures that assume that a file will
always be created. Note that /T has always been the default for /U
mode.
FILCOM was comparing too many locations in an EXE file compare. Do
not compare locations 0-40, 42, 43, 45-73, 77-111, 113, 114, and 132
inclusive. Also FILCOM had a bug where it was erroneously comparing
location 73.
The /I switch has been added. This switch causes FILCOM to do a
case-invariant compare. That is, files that are identical except for
case will have no differences.
3.0 KNOWN BUGS AND DEFICIENCIES
None.
4.0 INSTALLATION INSTRUCTIONS
There are no changes in the installation instructions.
FILCOM.DOC Page 3
5.0 INTERNAL CHANGES
None.
Significant Edit #s
76 Add support from ADP for /O - report label+offset in
differences file. This is useful for .MAC or .P11 files, since
it eliminates ambiguity in reporting the location of
differences.
100 Don't get confused if someone does a CCL RUN UUO.
101 Improve /U without /L
102 Fix parsing of =[sfd spec],[p,pn<cr><lf>
105 Add /T
113 FILCOM compares too many job data area locations. Do not
compare locations 0-40, 42, 43, 45-73, 77-111, 113, 114, and
132 inclusive. Also FILCOM had a bug where it was erroneously
comparing location 73.
114 Fix apparent fencepost error with /1L.
6.0 SUGGESTIONS
None.
[END OF FILCOM.DOC]