DECnet-20 Beware File
March 1982
VERSION 2.1
AA-J693B-TM
COPYRIGHT (C) 1979,1982 BY
DIGITAL EQUIPMENT CORPORATION, MAYNARD, MASS.
THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY BE USED AND
COPIED ONLY IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE AND
WITH THE INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS
SOFTWARE OR ANY OTHER COPIES THEREOF MAY NOT BE PROVIDED OR
OTHERWISE MADE AVAILABLE TO ANY OTHER PERSON. NO TITLE TO AND
OWNERSHIP OF THE SOFTWARE IS HEREBY TRANSFERRED.
THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
EQUIPMENT CORPORATION.
DIGITAL ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF
ITS SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DIGITAL.
DECnet-20 V2.1 Beware File Page 2
1.0 GENERAL INFORMATION
Decnet-20 V2.1 is a Maintenance Release for DECsystems
2040/2050/2060 only. RJE V1.0 is compatible with DECnet20-V2.1.
1.1 Installation of 32K Word DN20s
DECnet-20 V2.1 for DN20s with only 32K words of memory requires
special generation procedures, which are documented in the appendix.
DN20 systems with 32K words have no additional maintainability
features other than what was available in DECnet-20 V1. Thus, NCP
(Network Control Program) commands such as "SHOW {COUNTS|STATUS}
KNOWN LINES" and "SET STATE LINE line-id", which were unavailable
for DECnet-20 V1, will not work for 32K configurations in DECnet-20
V2.1.
2.0 BEWARE ITEMS
2.1 Acceptance Procedures
When running the DECnet-20 acceptance tests, AUTO-DUMP and
AUTO-LOAD for the DN20 front end must be disabled. Failure to do so
will prevent operation of the loopback tests. Any "node OFFLINE"
operator messages that appear during the loopback test should be
ignored.
2.2 DN20 System Cannot be Loaded if Generated Incorrectly
The hardware configuration options specified for the DN20
system image during network generation must be installed on the DN20
hardware for the system image to be successfully loaded. If
hardware is specified that does not exist, the DN20 node will crash
a few seconds after it is loaded. It is important to know exactly
what line interfaces are installed on the DN20 and generate the DN20
software for no more than this. If you plan to get more line
interfaces in the near future, you cannot generate them ahead of
time.
Failure to adhere to this restriction will prevent successful
installation of DECnet-20.
2.3 DN20 Crashes When Node Initialization is to Itself
If the DN20 attempts to node initialize over a line that is in
loopback, it will crash. The crash could be caused by installing a
loopback connector or by placing a modem in loopback on a line that
is in the ON state. See the suggestions section of the DOC file for
the proper method of performing line loopback.
DECnet-20 V2.1 Beware File Page 3
2.4 KMC/DUP Problem
There is a known problem with the KMC/DUP hardware. The
symptoms are that the KMC/DUP line becomes 'hung' and investigation
of the EIA interface reveals that the DN20 has Request-to-Send up
continuously. The problem is likely to happen whenever the modem on
the KMC/DUP line is powered on/off or is disconnected with the line
in the ON state.
To prevent this problem from happening, turn the line off with
the SET STATE LINE line-id OFF command prior to disconnecting or
powering off a modem on any line. The line can then be turned on
again when the modem is reconnected.
The simplest way to recover from this problem, should it occur,
is to reload the DN20.
2.5 DN20 crashes when Transmit Password is changed in NETGEN.
When doing a NETGEN for the DN20, the Transmit Password must be
DECNET20 (default). If this password is changed, the DN20 will
crash a few seconds after it finishes loading. Adjacent nodes that
require Node Verification must change their Receive Password for the
DECnet-20 node to DECNET20.
2.6 CLOSE problem.
The exec 'CLOSE' command does not close an aborted DECnet link,
however, the exec 'PUSH' command does close the link.
2.7 GNJFN% problem.
The GNJFN% JSYS does not step through directories correctly.
2.8 Loopback for local DMC.
The loopback test for the local DMC11 (DN21-BB) does not work.
The DN21-BB is a 56kbps integral line unit, includes one DMC11-AL
IPL microprocessor, once DMC11-MD line unit with integral modem, and
one BC03N-A0 coaxial cable.
DECnet-20 V2.1 Beware File Page 4
APPENDIX A
NETWORK GENERATION OF DECnet-20 V2.1 FOR 32K DN20
A.1 OVERVIEW
A 32K DN20 has marginal memory capacity for running DECnet-20
V2.1. To maintain most DECnet-20 V1 functionality, the 72-hour
testing (TEST72) capability on a production system has been dropped.
Consequently, users having a 32K DN20 will need to generate two DN20
systems, one for use during the acceptance procedures, and another
for use during production.
The acceptance procedure involving UETP (executing in the KL)
and TEST72 (executing in the DN20) can be run only by loading a DN20
that has TEST72 configured and does not have the Topology
Notification capability. Likewise, a production DN20 system must
have the Topology Notification capability and must not have TEST72
configured.
A.2 CONFIGURATION CONSTRAINTS
There are constraints on configuration options for a 32K DN20.
The configuration options are selected by commands to the NETGEN
program. The only supported 32K DN20 parameter values are:
o HARDWARE - Either 1 DUP11 (not a KMC-DUP combination) or
1 DMC11. [Note: this does NOT mean that you cannot run
a DN20 that has KMC-DUP hardware installed, just that the
KMC must not be configured.]
o SOFTWARE - 20 CCBs, 12 RDBs, and 8 SDBs; all other values
must be defaulted. The only exceptions to this are
identification parameters such as password, node-name,
and node-number.
NETWORK GENERATION OF DECnet-20 V2.1 FOR 32K DN20 Page A-2
A.3 EXAMPLES OF NETGEN TYPE-INS
During the generation procedure, it is advised that you create
a separate directory for each configuration to eliminate any
confusion. Examples of various configuration sessions are offered
below.
A.3.1 Acceptance Procedure Configuration
@RUN NETGEN
TOPS-20 Network Configurator for DN2x or DN200, Version: V2.1.2-39
NETGEN>EXCLUDE (from Configuration) KDP (number) 0
NETGEN>INCLUDE (in Configuration) DUP11 (number) 0
NETGEN>CCBS 20
NETGEN>RDBS 12
NETGEN>SDBS 8
NETGEN>EXCLUDE (from Configuration) TASK (type) Topology-Notification
NETGEN>SAVE ACC32K
NETGEN>FINISH
NETGEN>EXIT
@
A.3.2 Production Configuration
@RUN NETGEN
TOPS-20 Network Configurator for DN2x or DN200, Version: V2.1.2-39
NETGEN>EXCLUDE (from Configuration) KDP (number) 0
NETGEN>INCLUDE (in Configuration) DUP11 (number) 0
NETGEN>CCBS 20
NETGEN>RDBS 12
NETGEN>SDBS 8
NETGEN>EXCLUDE (from Configuration) TASK (type) 72-Hour-Test
NETGEN>SAVE PRO32K
NETGEN>FINISH
NETGEN>EXIT
@