TOPS20 Change Order Number 4.1.1074
Written by: DBELL 25-Jan-80 16:57:51
Edit checked: NO Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem:
There is a common need to store a full file spec with no missing fields.
However, specifying .JSAOF for all those fields in JFNS is a real pain.
Diagnosis:
There is no easy way to tell JFNS to do this common thing.
Solution:
Define a new symbol in MONSYM called JS%SPC which does the right things.
[End of TCO 4.1.1074]
TOPS20 Change Order Number 5.1055
Written by: ZIMA 1-Jun-80 23:54:12
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: YES
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem: MONSYM defines TL%AAD==1B7
Diagnosis: It should be TL%AAD==:1B7
Solution: Add the :
[End of TCO 5.1055]
TOPS20 Change Order Number 5.1105
Written by: OSMAN 22-Jul-80 09:04:14
Edit checked: NO Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem: No problem.
Diagnosis: PDVOP% symbol definitions needed in MONSYM.
Solution: Put them in.
[End of TCO 5.1105]
TOPS20 Change Order Number 5.1130
Written by: OSMAN 12-Aug-80 10:50:28
Edit checked: NO Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem: SEVEX1 error message is vague.
Diagnosis: It should refer to the length of the entry vector
Solution: Change wording of error message
[End of TCO 5.1130]
TOPS20 Change Order Number 5.1302
Written by: PAETZOLD 1-May-81 12:05:11
Edit checked: NO Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem: MONSYM doesn't know about .GOTRK or .GETYP
Diagnosis: They didn't use to exist
Solution: Add them
[End of TCO 5.1302]
TOPS20 Change Order Number 5.1355
Written by: CHALL 1-Jun-81 10:26:55
Edit checked: YES Document: YES
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's: 5.1356
Related SPR's:
Problem: NEED TO MAKE SOME FILES UNDELETABLE AND UNEDITABLE (LIKE THE
FRONT END).
Diagnosis:
Solution: DEFINE FB%NDL AS BIT 18 OF THE FILE DATA BLOCK. IF ON, THE FILE
CANNOT BE ALTERED OR DELETED.
ALSO DEFINE ERROR MESSAGE DELX13: "File cannot be changed or deleted"
[End of TCO 5.1355]
TOPS20 Change Order Number 5.1482
Written by: COBB 31-Aug-81 17:18:57
Edit checked: NO Document: NO
TCO Tested: NO Maintenance Release: NO
Hardware-related: NO
Program: MONSYM
Related TCO's:
Related SPR's:
Problem: error messages SYEX1 and SYEX2 refer to SYSERR.
Diagnosis: They refer to an obsolete feature.
Solution: Make them refer to SPEAR.
[End of TCO 5.1482]