Trailing-Edge
-
PDP-10 Archives
-
BB-4172H-BM
-
4-1-documentation/setspd.tco
There are 21 other files named setspd.tco in the archive. Click here to see a list.
18-Nov-82 12:16:30
*****************************************************************************
*** 21.SDC.1
*****************************************************************************
[S]
SETSPD requires SERCOD but dosen't need to.
[D]
As above.
[C]
Don't.
*****************************************************************************
*** 22.SDC.1
*****************************************************************************
[S]
Trailing spaces on a terminal speed command line can cause
problems.
[D]
SETSPD should get rid of them.
[C]
Eat trailing spaces.
*****************************************************************************
*** 23.SDC.1
*****************************************************************************
[SYMPTOM]
With PCO 20-MONITO-288 installed, lowercase printers may become
uppercase.
[DIAGNOSIS]
If the 4-CONFIG.CMD has PRINTER command lines without the
LOWERCASE keyword following lines with it for a given unit, the
lowercase setting is reset.
[CURE]
Make SETSPD latch any lowercase setting for a printer unit.
Alternatively, a user might include the LOWERCASE keyword on all
appropriate PRINTER commands in the 4-CONFIG.CMD file.
*****************************************************************************
*** 24.SDC.1
*****************************************************************************
[S]
SETSPD will not allow definition of a logical name containing a
"-".
[D]
TEXTI JSYS is used with the RD%PUN break set. This breaks on a
"-".
[C]
Check for "-" and if it is the break character then read the rest
of the logical name.
*****************************************************************************
*** 25.SDC.1
*****************************************************************************
[SYMPTON]
When booting the system SETSPD outputs the error message: COULD
NOT SET MTA X SERIAL XXXX.
[DIAGNOSIS]
SETSPD does not know about TU77 tape drives.
[CURE]
Add an entry in SETSPD's table to teach it about TU77's. Also be
certain to include TU77 on each line in the CONFIG file that
identifies a TU77 (i.e. MAGTAPE 0 1234 TU77).
*****************************************************************************
*** 26.SDC.1
*****************************************************************************
[S]
There is no BATCH-BACKGROUND command even though the system
managers guide says there should be.
[D]
The BATCH-BACKGROUND command is in SETSPDs command table as
BACKGROUND.
[C]
Change the name to BATCH-BACKGROUND.
*****************************************************************************
*** 27.SDC.1
*****************************************************************************
[SYMPTOM]
If the "ALL" keyword is used in the 4-CONFIG.CMD file to denote
times for automatic accounting shift change to occur, Fridays are
missed.
[DIAGNOSIS]
The argument for the keyword omits the bit for Friday.
[CURE]
Include the bit for Friday in the DOWTAB table.
*****************************************************************************
*** 28.SDC.1
*****************************************************************************
[SYMPTOM]
SETSPD needs to have version number set.
[DIAGNOSIS]
As above.
[CURE]
Set it for the monitor version and Autopatch edit level.
*****************************************************************************
*** 29.SDC.1
*****************************************************************************
[S]
NONE.
[D]
This edit is a tracking edit for another program version. No
actual code changes for this edit to this version have been generated.
[C]
NONE.
*****************************************************************************
*** 30.SDC.1
*****************************************************************************
[S]
NONE.
[D]
This edit is a tracking edit for another program version. No
actual code changes for this edit to this version have been generated.
[C]
NONE.
*****************************************************************************
*** 31.SDC.1
*****************************************************************************
[S]
Invalid help message pointer error when ? is typed in output
speed field of TERMINAL command.
[D]
BLT into command state block does wrong number of words.
[C]
Do correct BLT.
*****************************************************************************
*** 32.SDC.1
*****************************************************************************
[SYMPTOM]
TU45 is no longer used as the default magtape type if the type field
is left out of the CONFIG file.
[DIAGNOSIS]
Oversight.
[CURE]
Pass TU45 to COMND% as the default for the tape type field.
*****************************************************************************
*** 33.SDC.1
*****************************************************************************
[SYMPTOM]
When SETSPD gets an error reading the CONFIG file, the user has no way
of knowing which line was bad.
[DIAGNOSIS]
SETSPD uses routines from CMD to handle errors. CMD assumes the input
is from the terminal and does not echo the command line after an
error.
[CURE]
Move the necessary routines from CMD to SETSPD and add a routine to
output the command line before issuing the error message.