Google
 

Trailing-Edge - PDP-10 Archives - decuslib20-02 - decus/20-0026/data.sss
There are 2 other files named data.sss in the archive. Click here to see a list.
C                                                                       DATA  10
C     ..................................................................DATA  20
C                                                                       DATA  30
C        SAMPLE INPUT SUBROUTINE - DATA                                 DATA  40
C                                                                       DATA  50
C        PURPOSE                                                        DATA  60
C           READ AN OBSERVATION (M DATA VALUES) FROM INPUT DEVICE.      DATA  70
C           THIS SUBROUTINE IS CALLED BY THE SUBROUTINE CORRE AND MUST  DATA  80
C           BE PROVIDED BY THE USER.  IF SIZE AND LOCATION OF DATA      DATA  90
C           FIELDS ARE DIFFERENT FROM PROBLEM TO PROBLEM, THIS SUB-     DATA 100
C           ROUTINE MUST BE RECOMPILED WITH A PROPER FORMAT STATEMENT.  DATA 110
C                                                                       DATA 120
C        USAGE                                                          DATA 130
C           CALL DATA (M,D)                                             DATA 140
C                                                                       DATA 150
C        DESCRIPTION OF PARAMETERS                                      DATA 160
C           M - THE NUMBER OF VARIABLES IN AN OBSERVATION.              DATA 170
C           D - OUTPUT VECTOR OF LENGTH M CONTAINING THE OBSERVATION    DATA 180
C               DATA.                                                   DATA 190
C                                                                       DATA 200
C        REMARKS                                                        DATA 210
C           THE TYPE OF CONVERSION SPECIFIED IN THE FORMAT MUST BE      DATA 220
C           EITHER F OR E.                                              DATA 230
C                                                                       DATA 240
C        SUBROUTINES AND FUNCTION SUBPROGRAMS REQUIRED                  DATA 250
C           NONE                                                        DATA 260
C     ..................................................................DATA 270
C                                                                       DATA 280
      SUBROUTINE DATA (M,D)                                             DATA 290
C                                                                       DATA 300
      DIMENSION D(1)                                                    DATA 310
C                                                                       DATA 320
    1 FORMAT(12F6.0)                                                    DATA 330
C                                                                       DATA 340
C     READ AN OBSERVATION FROM INPUT DEVICE.                            DATA 350
C                                                                       DATA 360
      READ (5,1) (D(I),I=1,M)                                           DATA 370
C                                                                       DATA 380
C     INPUT DATA ARE WRITTEN ON LOGICAL TAPE 13 FOR THE RESIDUAL ANALY- DATA 390
C     SIS PERFORMED IN THE SAMPLE MULTIPLE REGRESSION PROGRAM.          DATA 400
C                                                                       DATA 410
      WRITE (13) (D(I),I=1,M)                                           DATA 420
      RETURN                                                            DATA 430
      END                                                               DATA 440